CARACTERÍSTICAS COMUNES
1.Build-incomputerdataprocessingandLCDdisplay:stableandreliablewiththefunctionsofintegralholding, pico heightandarea, autozeroadjusting, deuteriumlampbackgroundcorrection, curvesfitting multi-linearandnonlinear, variousparametersandworkingcurvesdisplayedinscreenandreportprinting, etc.. ITIS equippedwithinterfacefor externamente a la PC.
2.Stability:Double-beamsystemcanautomaticallycompensatethelightsourcedriftandwavelengthdrift originadopor thevariationof (withthefunctionof theeliminatingtheaffectionof wavelengthdrifton thebaseline estabilidad) andelectroniccircuitdrift soastoreach abueno línea básica estabilidad de temperatura.
3.Quickly: la lámpara de cátodo necesita longtimeandsamplecanbeanalyzedimmediately notbepre-heatedfor. Se isthepreferable instrumento elegido byusers toconduct análisis ofmultiple tipo ofelementsandfast analysisofsamples.
4.Highprecisionofmeasurement:Gaspathsystemisequippedwithprecisionpressurestabilizingandcurrent estabilizándose-ingdevicestoreachstableflameandlownoise. Garantizar la theflameto de Speciallydesignedfinelightbeampassesthrough ahighprecisionanalyticaltestandlowcharacteristicconcentration
5.Highenergyopticalpath:Atotalreflectionsystemisadoptedtoeliminatecolordifferenceinfullrange.by medios chemicalconversion, aroundlightspotofthelightsourcebecomesalonglightspot, whichenters intotheslit. Allí-
para flujo ligeroconsecutivo de la viga es.
6.Larga vidaandanti-corrosiveatomizationsystem:Theburnerismadeofnewtypetitaniumalloys, fastthermalequilibrium anti-corrosiveand. Itmeets la sensibilidad de ofmeasurement requisito sin refrigeración por agua.
7.Multi-functionalanalysismode:formethodsofflameabsorption, flameemission, graphitefurnaceatomic absorción y generación de hidruros.
8.Safeandreliablegaspathsystem:Specialdevicesofquickgasconversionandsafetyprotectioncanbe usanPara analyzeair-acetyleneflameaswellasnitrousoxide-acetyleneflameandextendtheanalytic elementstoreachmore de 60.
9.Completesetofaccessories: tobesuppliedwiththeinstrumentandreadyfor useaftertheyarepurchased.
Especificaciones
| WLrange | 190-900nm |
| WLaccuracy | ≤±0.5Nm |
| WLrepeatability | ≤0.3Nm(singledirection) |
| Spectrumbandwidth | 0.2nm 0.4nm 0.7nm, 1.4nm, 2.4nm, 5.0nm |
| Resolución | andlt; 40% andlt; TD = andquot; andquot; andgt; |
| Baselinestability | ±0.004Abs / 30 min |
| Characteristicconcentrationofcopper | ≤0.04μg/ml/1% |
| Detectionlimitofcopper | ≤0.008μg / ml |
| Backgroundcalibrationability | Greaterthan30times |
| RS232 | incluyendo |
| Impresora | opcional |
| Alimentación | 220V3A, 50Hz |
| G.W. | 160kg |
| 65kg | |
| PackageDimensions | 1220x770x730mm(Maininstrument) |
| 800x400x900mm(Accessories) |
ACCESORIOS ESTÁNDAR
Compresor de aire sin aceite
Atomizador de vidrio
Lámpara de cátodo hueco de Cu
Atomizador quemador unidad cubierta de polvo
Separación de agua filtro de gas
Quemador de titanio---10cm
ACCESORIOS OPCIONALES
Modelo sistema de horno de grafito HGA de GA3202
Tubos de grafito de generador de hidruro Software
Sistema de enfriamiento de agua de recirculación
Somos profesionales como uno de los principales aa320n absorción atómica espectrofotómetro fabricantes y proveedores en China. Bienvenido a venta por mayor de la alta calidad y equipo de laboratorio durable de nuestra fábrica. Y ofrecen buen servicio post-venta y entrega oportuna.
Etiqueta: aa320n espectrofotómetro de absorción atómica, China, fábrica, proveedor, fabrica, venta por mayor